Main application areas
It can be widely used for electromagnetic compatibility testing in IT products, household appliances, medical equipment, automotive parts, small military electronic products, industrial electronic products, communication fields, and more. After adding special interfaces, special product testing can be carried out, such as water meters, gas meters, electricity meters, etc.
Key Parameters
| Performance indicators | ||||||
| Performance parameters | Frequency range | Test area | Test height | Performance requirements | Reference standard | Test method |
|
Normalized Site Attenuation NSA |
30MHz-1GHz | 3.0m (or larger size) | H=2.0m | Better than ± 3.5dB | CISPR16-1-4 2010 | 3m/5m central axis testing |
|
Field Uniformity FU |
30MHz-1GHz | 1.5mx1.5m | H=0.8m~2.3m | 0~5.5dB |
IEC61000-4-3 and EN61000-4-3 |
3m central axis testing |
|
Site Voltage Standing Wave Ratio SVSWR |
1GHz~18GHz | 5.0m (or larger size) | H=2.5m | ≤5.5dB | CISPR16-1-4 | 3m/5m central axis testing |
| Background Noise | 30MHz~18GHz | / | ≤20dB |
CISPR 22 Class B CISPR 25 Class 5 |
||