10-Meter Anechoic Chamber

The SAC-10M is a semi-anechoic chamber designed for a test distance of 10 meters. It mainly consists of a main anechoic chamber, a control room and a power amplifier room, and is used for radiation immunity tests and compliance tests of radiation emissions at distances of 10 meters or 3 meters. SAC-10M is the most widely used standard test environment, mainly designed to meet the testing requirements of large-sized electronic systems and the industry testing standards of some electronic products. It can also be configured for 3m testing, and its quiet zone can be expanded to a diameter of 5 meters or even larger.

Main application areas

Test distance: The core feature of a 10-meter anechoic chamber is a test distance of 10 meters, which helps to reduce interference caused by reflection, thereby enhancing the accuracy and consistency of the test.
Structural composition: The 10-meter anechoic chamber for radio waves is typically composed of a main anechoic chamber, a control room, a power amplifier room, and other parts. The interior of the main anechoic chamber is lined with absorbing materials to absorb electromagnetic waves, prevent reflection and ensure the quietness of the testing environment.
Testing capability: It can conduct electromagnetic compatibility tests such as radiation emission tests, radiation immunity tests, and shielding effectiveness tests. In addition, it can also meet the requirements of various international and national standards, such as CISPR, IEC, GJB, etc.
Technical indicators: The 10-meter anechoic chamber has five key technical indicators, including shielding effectiveness, normalized field attenuation, field voltage standing wave ratio, field uniformity and environmental noise. These indicators directly affect the accuracy and reliability of the test.
Scope of application: The 10-meter anechoic chamber is suitable for radiation disturbance and immunity tests of various types of electronic equipment, communication equipment, automotive electronic equipment, industrial, scientific and medical equipment, etc.

Key Parameters

Performance indicators
Performance parameters Frequency range Test area Test height Performance requirements Reference standard Test method

Normalized Site Attenuation

NSA

30MHz-1GHz Dia 6.0m H=2.5m Better than ± 3.5dB CISPR16-1-4 2010 10m central axis testing

Field Uniformity

FU

30MHz-1GHz 1.5mx1.5m H=0.8m~2.3m 0~5.5dB

IEC61000-4-3 and

EN61000-4-3

10m central axis testing

Site Voltage Standing Wave Ratio

SVSWR

1GHz~18GHz Dia 5.0m H=2.5m ≤5.5dB CISPR16-1-4 10m central axis testing
Background Noise 30MHz 18GHz ≤20dB

CISPR 22 Class B

 CISPR 25 Class 5

Design and Configuration

The design and configuration of the 10m anechoic chamber can be customized according to specific requirements. For instance, it can be equipped with different specifications of absorbing materials, turntables, antenna towers and filters, etc. In addition, different interfaces and additional functions can be selected as needed, such as emergency control/alarm systems.
summary
To sum up, the 10-Meter Anechoic Chamber is a professional facility for electromagnetic compatibility testing. By maintaining a test distance of 10 meters, it provides a controlled environment close to open field conditions to ensure the accuracy and repeatability of test results. It is widely used in the radiation emission and immunity tests of various electronic devices, and can be customized and configured according to specific needs.